Try adjusting your search or filter options.
LPH stands for Liters Per Hour. A 5000 LPH RO Plant is a high-capacity reverse osmosis water purification system that can purify roughly 5,000 liters of water every hour under ideal operating conditions. This is not a small domestic purifier — it’s industrial or commercial grade, intended for large daily or hourly water demand.
Typical Use Cases:
Factories/manufacturing units that need clean process or utility water
Hotels, banquet halls, and large commercial buildings
Large institutions: colleges, hospitals, labs
Water dispensing / ATMs / kiosks
Bottled water or packaged water operations
Large residential complexes or community water-supply systems
Because of the scale, a 5000 LPH RO Plant involves significant planning: pre-treatment, membrane configuration, power supply, and the outlet (tap) design all matter deeply.
To run a 5000 LPH system well, you need to know its major parts — and especially understand how the RO Tap and RO Tap Connector play a key role.
Pre-Filtration
Sediment/multimedia filter: Removes sand, dirt, rust.
Activated Carbon Filter: Takes out chlorine, organic matter, and protects RO membranes.
Micron / Cartridge Filters: Gives finer filtration so the membrane isn’t clogged by small particles.
High-Pressure Pump
The heart of the system: pushes feed water through the RO membranes at the required pressure.
RO Membranes
Typically, Thin-Film Composite (TFC) membranes in industrial systems.
These membranes reject most dissolved salts (TDS), heavy metals, and other contaminants.
Antiscalant / Chemical Dosing (Optional but Common)
A dosing pump may inject antiscalant to prevent scale formation on RO membranes, which helps maintain performance and longevity.
Post-Treatment
TDS Controller / Remineralizer: Adds back healthy minerals or adjusts TDS to required levels.
UV / UF: (Optional) for microbial disinfection or “polishing” the water.
Automation & Control
Float switches/level sensors: For automatic shut-off when the storage tank is full.
Control panel/instrument panel: To monitor pump status, alarms, and operational parameters.
Pressure gauges: To monitor feed pressure, permeate pressure, and reject pressure.
Structural Frame / Skid
Made of Stainless Steel (SS) or FRP (Fiber Reinforced Plastic).
Supports all components: filters, membrane housings, pump, piping.
Electrical System
Supplies the high-pressure pump, control panel, sensors, and dosing pump.
Typically designed for industrial power supply, possibly three-phase depending on the design.
RO Tap & RO Tap Connector
RO Tap: The faucet or outlet from which purified water is drawn out.
RO Tap Connector: A specialized fitting that connects the purified water (permeate) line to the tap or distribution piping.
Importance in 5000 LPH Systems: At such high flow, the connector must be robust (food-grade), correctly rated for pressure and volume, and reliable. Poor connectors can leak, restrict flow, or become a weak point in the system.
Here are representative specs for a 5000 LPH RO Plant, based on real manufacturer / vendor data:
| Specification | Typical / Example Value |
|---|---|
| Capacity (Purified Water) | ~5,000 LPH as rated by major RO plant manufacturers |
| Pre-Filtration | Usually includes sand + activated carbon + cartridge filters |
| Antiscalant Dosing | Often included: two dosing pumps in some models |
| Membrane Configuration / RO Vessels | Example: 5 RO membranes (80 × 40 size) in stainless / FRP housings in Soni Water Care model |
| Pump | High-pressure multistage pump (vertical/centrifugal) in many designs |
| Frame / Skid Material | Options: FRP (industrial), or SS (stainless steel) for very robust builds |
| Automation | Fully automatic or semi-automatic depending on model; control panels + indicators |
| Operating Power | Many units use industrial three-phase power; exact voltage depends on the design |
| Recovery Rate | Designed for moderate recovery, dependent on feed water quality and design (typical industrial RO) |
| Warranty / Service | Many vendors (like ROSP V AQUA) mention periodic maintenance and membrane replacement |
Let’s look at how much a 5000 LPH RO Plant costs in India, based on real-world quotes, plus factors that influence cost.
Here are several vendor/manufacturer price points for 5000 LPH RO Plants:
RO Care India (Hitech 5000 LPH): ₹ 475,000 for a 5000 LPH RO Plant with 7-stage purification.
Doctor Fresh 5000 LPH RO Plant: Their model (with RO + UV + Iron removal + TDS infuser + PSS) is priced at ₹ 490,000.
Soni Water Care: 5000 LPH RO Plant (SS skid) — ₹ 550,000.
Jei Aqua Tech: 5000 LPH RO Plant, SS body, fully automatic — ₹ 726,100.
Arise Engineering: 5000 LPH SS RO Plant: quoted at ₹ 650,000 for semi-automatic design.
Aqua Pristine: 5000 LPH Industrial RO Plant (FRP) — ₹ 380,000.
Spark Aqua Solutions: 5000 LPH Industrial RO Plant (automatic) — ₹ 767,000 (as per TradeIndia listing).
Aqua Fresh Water Technology: Fully automatic 5000 LPH RO Plant — ₹ 160,000 per TradeIndia listing. (This seems unusually low for 5000 LPH; check with vendor for specs/reliability.)
These are major factors that influence the cost of a 5000 LPH RO Plant:
Material of Construction
FRP (Fiber Reinforced Plastic) is generally cheaper but may not be as durable or strong as stainless steel (SS).
SS skid / frame increases cost due to material and fabrication.
Membrane Quality and Number
Number of RO membranes (e.g., 4, 5, or more)
Quality / brand of membranes (premium TFC membranes cost more).
Pump Specification
Higher capacity, branded, or efficient high-pressure pumps will cost more.
Pre- & Post-Treatment Stages
Inclusion of sand, carbon filters
Dosing pumps (antiscalant)
UV, TDS infuser, remineralization modules
Automation
Control panel, sensors (level, pressure), auto-flush / cleaning features.
Installation & Commissioning
Civil base / skid mounting, piping, plumbing, electrical wiring.
Service, Warranty & Spare Parts
Longer warranty or AMC (Annual Maintenance Contract) costs more.
Spare parts like membranes, connectors, valves need to be factored in.
RO Tap Connector & Distribution Plumbing
High-quality RO Tap Connector and piping to outlet points.
Based on the data above:
Lower to Mid Spec (FRP, semi/auto): ~₹3.8 lakh (Aqua Pristine example) to ~₹5.0 lakh (V AQUA)
Mid to Higher Spec (SS skid, good membranes, auto): ~₹5.5–7.5 lakh (V AQUA SS, Jei Aqua, Arise Engineering).
Premium or Specialized Config: ₹7.5+ lakh depending on the design, number of membranes, post-treatment, and automation.
Here are real-world 5000 LPH RO Plant models/product variants from different manufacturers:
V AQUA – 5000 LPH RO Plant: Very high-capacity industrial/commercial plant from ROSP.
Soni Water Care – 5000 LPH RO Plant: Stainless steel skid, automatic, antiscalant dosing.
Doctor Fresh – 5000 LPH RO + UV + Iron Removal + TDS Infuser + PSS: All-in-one purification system.
Jei Aqua Tech – 5000 LPH RO (SS): Energy-efficient design, stainless steel body.
Arise Engineering – 5000 LPH SS RO Plant: Semi-automatic, SS frame.
Aqua Pristine – 5000 LPH Industrial RO Plant (FRP): Semi-automatic, corrosion-resistant FRP frame.
Spark Aqua Solutions – 5000 LPH Industrial RO Plant: Automatic grade, commercial use.
Aqua Fresh Water Technology – Fully Automatic 5000 LPH RO Plant: Listed on TradeIndia; electric drive.
Given its high capacity, a 5000 LPH RO Plant is well suited for:
Industrial Applications
Manufacturing/process water in food, beverage, pharmaceuticals, or chemical industries
Boiler feed or utility water (if purity requirements are moderate)
High-purity water for sensitive processes
Large Commercial / Institutional Settings
Hotels / resorts / banquet halls for drinking water and catering
Colleges, hostels, schools for supplying purified water to many people
Hospitals, labs, diagnostic centers requiring a large, reliable supply of RO water
Water Vending / ATM / Kiosk
A 5000 LPH unit can feed a high-throughput water vending machine or ATM, enabling water commercialization.
Useful for community water points or public drinking water distribution.
Bottled or Packaged Water Plants
Suitable capacity for a mid-sized bottled water operation or packaged drinking water line.
Can supply RO water for filling bottles, or for PPC (pre-process) water.
Community / Residential Complexes
Large apartments, housing societies, or gated communities can use a central 5000 LPH RO plant to supply drinking water.
Shared infrastructure for cost efficiency rather than individual RO purifiers in each home.
Here are major benefits:
Very High Throughput — 5000 liters/hr can meet large-scale demand reliably.
Economy of Scale — With a large plant, cost per liter falls significantly (compared to many small units).
Industrial-Grade Durability — Designed to handle continuous operation, with strong membranes and pumps.
Flexible Customization — Option to choose frame (FRP / SS), automation, membrane count, post-treatment (UV, infuser).
Better Water Quality — RO effectively reduces dissolved salts, heavy metals, and many impurities.
Scalability — Future upgrades or modular additions are often possible.
Sustainable Use — With reject water recycling, waste can be significantly minimized.
Deploying a 5000 LPH RO Plant has some challenges:
Power Demand and Stability
High-pressure pump will need reliable electrical supply; fluctuations can damage equipment.
Raw Water Quality Variability
If the feed water has high TDS, turbidity, or organics, pre-treatment design must be robust, or else membranes will degrade.
Maintenance Needs
Filters, membranes, pumps, and dosing systems all need regular maintenance.
Reject Water Management
RO systems reject a certain percentage of feed water; without a plan, this could be wasteful or expensive to dispose of.
Capital Expenditure (CapEx)
The plant is a significant investment; ROI depends on usage or business model (sale of water, internal load, etc.).
Quality of RO Tap Connector and Outlet Piping
Using the right RO Tap Connector is crucial. Poor connectors may leak or fail, especially under heavy flow.
Installation Complexity
Requires proper foundation, piping, storage tanks, and possibly skilled technicians for commissioning.
Training and Operation
Operators must be trained to maintain and troubleshoot the system (monitor pressures, TDS, pump behavior).
To keep a 5000 LPH RO Plant running well:
Replace Pre-Filters: Regularly change or clean the sediment and carbon filters based on usage and water quality.
Monitor and Clean Membranes: Use TDS / conductivity meters to monitor permeate quality; run periodic cleaning cycles (CIP) if supported.
Pump Maintenance: Inspect the high-pressure pump for vibration, noise; maintain bearings, seal integrity.
Dosing System: For antiscalant dosing, verify pump operation, chemical levels, and reservoir.
Flush Cycles: Use auto or scheduled flush cycles if the system supports them.
Inspect RO Tap Connectors: Frequently check for leaks, wear, or damage at the outlet.
Record Keeping: Maintain logs of production, reject volumes, maintenance tasks, and part replacements.
Water Quality Testing: Periodically test the purified water (TDS, possibly microbial) to ensure system performance.
Spare Parts: Keep key spare parts (RO membranes, filter cartridges, valves, and connectors) in stock.
Service Contract: Consider an AMC (Annual Maintenance Contract) with the vendor/manufacturer to minimize downtime.
Here’s how a 5000 LPH RO Plant can justify its cost and deliver return:
Cost Efficiency: Instead of multiple smaller RO units or buying water, one large plant produces a lot of purified water at lower cost per liter.
Revenue Potential: If used in a water ATM/kiosk or selling water to other users (factories, offices), you can monetize the output.
Asset Longevity: RO membranes and pumps in industrial systems are built for durability, so long-term costs per liter go down.
Reject Water Reuse: With a plan to reuse reject water (for cleaning, non-drinking uses), you minimize water wastage and increase resource efficiency.
Scalability: Modular capacity means you can expand without replacing the entire system.
Sustainability: A large RO Plant can replace reliance on bottled water, reduce plastic usage, and centralize purified water infrastructure.
Here’s a practical checklist to help you make the right decision:
Estimate Your Demand
How many liters/day, peak demand, and usage pattern?
Do you need to store purified water or pump it directly?
Analyze Your Feed Water
Get a full water test: TDS, turbidity, hardness, organics, microbial load.
Design pre-treatment (sand, carbon, micron) based on this.
Pick Skid Material
FRP (cheaper, corrosion-resistant) vs Stainless Steel (durable, hygienic).
Decide Automation Needs
Manual vs semi-automatic vs fully automatic (panel, sensors, flush, CIP).
Membrane Configuration
How many RO membranes, what capacity per membrane, what quality/brand.
Post-Treatment Requirements
Do you need UV, TDS infuser, remineralizer, iron removal, or more?
Design the Outlet / Tap
How will purified water be drawn? (Tap, tank, filling station)
Choose correct RO Tap Connector and plumbing for durability under flow.
Choose a Reliable Supplier
Check for service network, spare part availability, and past project references.
Budget Everything
Consider not just the plant cost, but installation, operation, maintenance, spare parts.
Ask for Documentation
Request:
5000 LPH RO Plant Quotation PDF (detailed cost)
Specification Sheet / PDF (technical details)
Process / Flow Diagram (pre-filters, RO, reject, outlet)
Operation & Maintenance Manual
Warranty / AMC Terms
Ensures high-quality membranes, robust pumps, and reliable connectors (especially RO Tap Connector).
Access to genuine documentation (spec sheets, diagrams, quotes).
Better after-sales service, spare part support, and maintenance.
Safer installations: experienced vendors ensure proper plumbing, power wiring, and commissioning.
Ability to customize: skid material, automation, number of membranes, and post-treatment.
When evaluating potential sellers, make sure you get or ask for:
A 5000 LPH RO Plant Quotation PDF — with itemized costs: pump, membranes, piping, installation, control panel, etc.
A Specification / Data Sheet PDF — capacity, power, recovery rate, number of membranes, materials.
A Process / Flow Diagram — showing how raw water comes in, goes through pre-filters, RO stage, reject, and out via tap or storage.
An Operation & Maintenance Manual — filter replacement intervals, cleaning schedule, recommended spare parts.
Details on Warranty and AMC (Annual Maintenance Contract) — parts and labor coverage.
A Spare-Parts List — membranes, RO Tap Connectors, valves, filter cartridges, etc.
To ensure your 5000 LPH RO Plant remains valuable and efficient in the long run:
Modular Design: Make sure the system can be expanded by adding more RO modules if needed.
Auto-Flush or CIP: Incorporate periodic cleaning cycles to maintain membrane life.
Reject Water Reuse: Plan a pipeline to reuse reject water (for cleaning, flushing, or non-potable uses).
Add Monitoring: Use flow meters, TDS meters, or even remote / IoT monitoring for performance tracking.
Consider Post-Treatment Upgrades: UV, remineralizer, or other features can be added later.
Maintain a Spares Inventory: Keep critical spares ready – membranes, connectors, filters.
Service Agreement: Lock in an AMC now, even if you don’t fully use it, to reduce future downtime.
Here are common risks with a 5000 LPH RO Plant and how to mitigate them:
Risk: Power fluctuations damaging pump
Mitigation: Use stabilizer / UPS and ensure proper power infrastructure.
Risk: Scale on RO membranes from hard or dirty water
Mitigation: Use antiscalant dosing + robust pre-filtration.
Risk: Reject water waste
Mitigation: Reuse reject water for flushing/cleaning or non-potable uses.
Risk: Connector failure (tap leak or blow-out)
Mitigation: Use food-grade, high-quality RO Tap Connectors and check them regularly.
Risk: Maintenance neglect
Mitigation: Schedule maintenance, log operations, use an AMC.
Risk: Poor installation
Mitigation: Hire experienced technicians, follow vendor guidelines, test system thoroughly at commissioning.
A 5000 LPH RO Plant is a very high-capacity, industrial/commercial RO system meant for large-scale water purification needs.
Choosing a good RO Tap Connector is critical — it must handle high flow, pressure, and be durable.
In India, the typical price for 5000 LPH RO Plants ranges broadly (from ~₹3.8 lakh for FRP to ~₹7.5+ lakh for SS, depending on the vendor and specification).
Maintenance, reject-water management, and power consumption are major operational considerations.
For ROI, consider whether the system will serve internal demand, water vending, or other commercial use.
When purchasing, ask for detailed quotation PDF, specification sheet, flow diagram, maintenance plan, and AMC terms.
Plan future-proofing: modular expansion, reject reuse, and monitoring systems.